Send the request
Menu

A housing's footprint starts at the melting furnace

The furnace burns gas for all the plant's metal. The model reads each month's gas off the bill, and plain code splits the melting share by the melt each part takes.

Melt is gross shot weight per part, runners and scrap included. Estimated months are marked.

See the file

Every machine's electricity, split to the parts that ran on it

Power per cost center is rated power times hours, scaled to the month's measured total, or a submeter's reading. The model proposes each key and a person accepts it once. Average machine values stand where representative, as Catena-X allows.

Holding furnaces

hours each part held metal

Die-casting cells

cycle time times parts made

Trim presses

strokes, one per shot

Machining centers

machine hours booked to the part

Compressed air

running hours of the cells it feeds

Offices, lighting, canteen

over all parts by machine hours, so nothing metered is left out

See it worked
Alloy ingot, 24 tonnes
Example: three ranked factors for 24 tonnes of alloy ingot: the supplier's own declaration, secondary aluminum, Europe, from a database, primary aluminum last.
Example: alloy ingot from the die-caster's Slovenian refiner.

Ranked.

For each input the model ranks up to three emission factors, each with its source and reason, as a published study of factor recommendation proposes. You pick one.

A supplier's declared figure ranks first when its method, period and unit are stated.

Database figures follow: ecoinvent 3.12, which we license, or national factors.

Supplier's declaration
same supplier and alloy, 2025, method stated
Secondary aluminum, Europe
same route and region, but an average
Primary aluminum
last: the invoice says secondary alloy

Every measured reading the model reads takes the place of an average

62%

of the example housing's footprint is measured or declared data

Example: the gearbox housing. The other 38% rests on database figures for the second ingot supplier and the minor inputs, and shrinks when that supplier declares.

A supplier-specific footprint can still rest over 80% on market averages upstream.

In the WBCSD pilot, primary and secondary footprints differed by 37% on average.

Database averages

Measured at the plant, declared by a supplier

Your request has been received.

Expect a message from Perpezzo. It goes to the address you gave.